About DIXELL CONTROLLER XR30CX-5NOC1
Digital controller with defrost and fans management XR40CX 1. GENERAL WARNING __________________________________________________________ 1 2. GENERAL DESCRIPTION ______________________________________________________ 1 3. CONTROLLING LOADS ________________________________________________________ 1 4. FRONT PANEL COMMANDS ____________________________________________________ 1 5. MAX & MIN TEMPERATURE MEMORIZATION _____________________________________ 1 6. MAIN FUNCTIONS ____________________________________________________________ 2 7. PARAMETERS _______________________________________________________________ 2 8. DIGITAL INPUTS _____________________________________________________________ 3 9. RS485 SERIAL LINE FOR MONITORING SYSTEMS _______________________________ 4 10. X-REP OUTPUT OPTIONAL ___________________________________________________ 4 11. INSTALLATION AND MOUNTING ________________________________________________ 4 12. ELECTRICAL CONNECTIONS___________________________________________________ 4 13. USE THE HOT KEY ___________________________________________________________ 4 14. ALARM SIGNALS _____________________________________________________________ 4 15. TECHNICAL DATA ____________________________________________________________ 4 16. CONNECTIONS ______________________________________________________________ 4 17. DEFAULT SETTING VALUES ___________________________________________________ 4 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument shall not be used for purposes different from those described hereunder. It cannot be used as a safety device. Check the application limits before proceeding. 1.2 SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation Warning: disconnect all electrical connections before any kind of maintenance. Fit the probe where it is not accessible by the End User. The instrument must not be opened. In case of failure or faulty operation send the instrument back to the distributor or to Dixell S.r.l. (see address) with a detailed description of the fault. Consider the maximum current which can be applied to each relay (see Technical Data). Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining. In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with inductive loads could be useful. Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality. 2. GENERAL DESCRIPTION Model XR40CX, format 32x74 mm, is a microprocessor based controller suitable for applications on medium or low temperature ventilated refrigerating units. It has two relay outputs to control compressor and fans. It could be provided with a Real Time Clock which allows programming of up to 6 daily defrost cycles, divided into holidays and workdays.It is also provided with up to four NTC or PTC probe inputs: the first one for temperature control, the second one (to be located onto the evaporator) to managed the fan, the third one to signal the condenser temperature alarm and the fourth one as additional temperature probe. By connecting an XJ485-CX external module to the HOT-KEY port, it is possible to link the controller to a ModBUS-RTU compatible network line (such as any dIXEL X-WEB family monitoring unit). It is also possible to program the controller by using an external HOT-KEY memory device. The instrument is fully configurable through special parameters that can be easily programmed through the frontal keyboard 3. CONTROLLING LOADS 3.1 COMPRESSOR The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters Con and CoF. 3.2 DEFROST Two defrost modes are available through the tdF parameter: defrost through electrical heater (tdF=EL) and hot gas defrost (tdF=in). The defrost interval depends on the presence of the RTC (optional). If the RTC is present is controlled by means of parameter EdF: - with EdF=in the defrost is made every idF time standard way for controller without RTC. - with EdF=rtC the defrost is made in real time Other parameters are used to control the interval between defrost cycles (idF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporators probe (P2P).
Superior Environmental ControlThe XR30CX-5NOC1 ensures accurate regulation of temperature and humidity within refrigeration units. Its robust system supports both heating and cooling functions, ideal for environments requiring stable thermal management. The wide operational range enhances performance in challenging conditions.
User-Friendly and Durable DesignCrafted from high-quality black PVC, the controller is built to withstand regular industrial use while maintaining an unobtrusive appearance. The compact size allows for easy integration within existing systems, and the intuitive user interface streamlines programming and monitoring tasks.
Versatile Application and Reliable PerformanceSupporting defrost and fan operations, the controller meets diverse refrigeration demands. Operating on a standard 230V supply and accepting loads up to 3.5A, the XR30CX-5NOC1 adapts to various set-ups seamlessly, ensuring continuous reliability for critical temperature-control applications.
FAQ's of DIXELL CONTROLLER XR30CX-5NOC1:
Q: How do I install the DIXELL CONTROLLER XR30CX-5NOC1 in my refrigeration system?
A: To install the XR30CX-5NOC1, mount it in a suitable location within your control panel, ensuring the dimensions (32 x 74 x 50 mm) fit your space. Follow wiring diagrams provided by Dixell, connect to power (230V) and relevant fan, heating, or cooling outputs. Always ensure installation is by a qualified technician in accordance with safety standards.
Q: What applications is the XR30CX-5NOC1 best suited for?
A: This controller excels in commercial and industrial refrigeration applications requiring precise temperature or humidity control, such as cold rooms, display fridges, and freezers. Its defrost and fan management functions make it especially useful in environments where consistent cooling and heating is vital.
Q: When should I consider using the XR30CX-5NOC1 for my cooling or heating system?
A: If you need automated temperature management with reliable defrost and fan control functions, especially within environments operating between 0 to 60C and 20 to 85% relative humidity, the XR30CX-5NOC1 is a suitable choice. It benefits both retrofit and new installations requiring enhanced system efficiency.
Q: Where can I use the DIXELL XR30CX-5NOC1 considering its humidity and temperature range?
A: You can utilize the XR30CX-5NOC1 in locations where humidity stays within 20 to 85% (non-condensing) and temperatures remain between 0 and 60C. This makes it ideal for controlled indoor settings like refrigerated warehouses, supermarkets, and industrial cold storage facilities.
Q: What process does the XR30CX-5NOC1 use for defrost and fan management?
A: The controller automates defrost and fan operations based on programmable temperature and time parameters, ensuring that frost buildup is minimized and airflow remains optimal, thus maintaining product safety and operational efficiency.
Q: How does the XR30CX-5NOC1 benefit my refrigeration system?
A: By delivering precise control over heating, cooling, defrost, and fan operations, the XR30CX-5NOC1 improves energy efficiency, extends equipment lifespan, and helps maintain consistent storage conditions, protecting sensitive goods from spoilage.