About DIXELL CONTROLLER XR03cx-5noc1
DIGITAL CONTROLLER
XR03CX XR04CX
1. CONTENTS
1. Contents __________________________________________________________________________ 1
2. General warnings ___________________________________________________________________ 1
3. General description __________________________________________________________________ 1
4. Regulation _________________________________________________________________________ 1
5. Defrost____________________________________________________________________________ 1
6. Front panel commands _______________________________________________________________ 1
7. Parameters ________________________________________________________________________ 2
8. Digital inputs _______________________________________________________________________ 2
9. Installation and mounting _____________________________________________________________ 2
10. Electrical connections ________________________________________________________________ 2
11. How to use the hot key _______________________________________________________________ 2
12. Alarm signalling _____________________________________________________________________ 2
13. Technical data ______________________________________________________________________ 3
14. Connections _______________________________________________________________________ 3
15. Default setting values ________________________________________________________________ 3
2. GENERAL WARNING
PLEASE READ BEFORE USING THIS MANUAL
1. This manual is part of the product and should be kept near the instrument for easy and quick
reference.
2. The instrument shall not be used for purposes different from those described hereunder. It
cannot be used as a safety device.
3. Check the application limits before proceeding.
4. Dixell Srl reserves the right to change the composition of its products, even without notice,
ensuring the same and unchanged functionality.
SAFETY PRECAUTIONS
Check the supply voltage is correct before connecting the instrument.
Do not expose to water or moisture: use the controller only within the operating limits avoiding
sudden temperature changes with high atmospheric humidity to prevent formation of
condensation
Warning: disconnect all electrical connections before any kind of maintenance.
Fit the probe where it is not accessible by the End User. The instrument must not be opened.
In case of failure or faulty operation send the instrument back to the distributor or to Dixell
S.r.l. (see address) with a detailed description of the fault.
Consider the maximum current which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough
from each other, without crossing or intertwining.
In case of applications in industrial environments, the use of mains filters (our mod. FT1) in
parallel with inductive loads could be useful.
3. GENERAL DESCRIPTION
The XR03CX, in 3274x50mm short format, is microprocessor based controller suitable for applications on
normal temperature refrigerating units. It provides two relay output: one for compressor and the other one for
alarm signalling or as auxiliary output. It provides an NTC probe input and a digital input for alarm signalling,
for switching the auxiliary output or for start defrost. The instrument is fully configurable through special
parameters that can be easily programmed through the keyboard or the by HOTKEY.
The XR04CX, in 3274x50mm short format, is microprocessor based controller suitable for applications on
normal or low temperature refrigerating units. It provides two relay output: one for compressor and the other
one for defrost. It provides two NTC probe inputs, one for room temperature and other one to control defrost
termination. The instrument is fully configurable through special parameters that can be easily programmed
through the keyboard or the by HOTKEY.
4. REGULATION
The regulation is performed according to
the temperature measured by the
thermostat probe with a positive
differential from the set point: if the
temperature increases and reaches set
point plus differential the compressor is
started and then turned off when the
temperature reaches the set point value
again.
In case of fault in the thermostat probe the start and stop of the compressor are timed through
parameters Cy and Cn.
5. DEFROST
XR03CX
Defrost is performed through a simple stop of the compressor. Parameter id
Reliable Performance for Chilling ApplicationsThe DIXELL XR03cx-5noc1 controller is crafted to deliver precise control in chilling systems. Its robust PVC body and efficient design provide consistent performance in demanding environments. Its compact size makes installation easy, while its wide temperature range supports a variety of cooling needs. This controller contributes to energy efficiency and prolongs equipment lifespan by maintaining optimal conditions.
Simple Operation and SetupThis controller features a straightforward SETTING operating method, allowing users to quickly configure temperature settings between 0 to 60C. Suitable for both professionals and beginners, the user-friendly interface ensures hassle-free adjustments and real-time monitoring. This simplicity helps minimize setup times while reducing the chance of operational errors.
FAQ's of DIXELL CONTROLLER XR03cx-5noc1 :
Q: How do I install the DIXELL CONTROLLER XR03cx-5noc1 in my chilling system?
A: To install the DIXELL XR03cx-5noc1, securely mount the unit using its compact dimensions (32 x 74 x 50 mm) within your system. Connect it to a 230V power supply and integrate the temperature sensors according to your chilling application requirements. Always consult the wiring schematic for accurate setup.
Q: What are the benefits of using this controller for chilling applications?
A: The DIXELL XR03cx-5noc1 provides accurate temperature control, helping maintain product quality and energy efficiency in chilling systems. Its precise regulation supports consistent operation, reduces system wear, and helps optimize energy consumption, leading to cost savings over time.
Q: When should I adjust the temperature settings on the controller?
A: You should adjust the settings when there are changes in chilling requirements, such as new cooling loads or seasonal variations. The SETTING operation method allows quick and easy modifications to ensure your system stays within the desired temperature range of 0 to 60C.
Q: Where is this controller best utilized?
A: This controller is ideal for use in commercial and industrial chilling applications, including cold rooms, display cases, and refrigeration units that require stable and monitored temperature control.
Q: What is the process for changing operational modes on this controller?
A: To change operational modes, use the interface panel to navigate the SETTING options. Follow the user instructions to adjust modes and set parameters to match your specific chilling system's requirements.
Q: How does using the DIXELL XR03cx-5noc1 benefit the lifespan of my cooling equipment?
A: Consistent temperature regulation by the DIXELL controller reduces stress on cooling components, preventing frequent cycling and minimizing wear. This leads to prolonged equipment life and fewer maintenance hassles.