DIXELL CONTROLLER XR08CX-5NOC1 Specification

  • Product Type
  • CONTROLLER
  • Voltage
  • 230 Volt (v)
  • Dimension (L*W*H)
  • 32 X 74 X 50 Millimeter (mm)
  • Application
  • MILK CHILLER
  • Material
  • PVC
  • Usage
  • CONTROL SYSTEM
  • Weight
  • 0.5 Grams (g)
  • Color
  • BLACK
  • Temperature Range
  • 3 Delisle
 

DIXELL CONTROLLER XR08CX-5NOC1 Trade Information

  • Minimum Order Quantity
  • 5 Number
  • Delivery Time
  • 3 Days
 

About DIXELL CONTROLLER XR08CX-5NOC1

Milk tank controllers
XR08CX
1. GENERAL WARNING ........................................................................................................... 1
2. GENERAL DESCRIPTION .................................................................................................... 1
3. CONTROLLING LOADS ....................................................................................................... 1
4. AGITATION CYCLE .............................................................................................................. 1
5. FRONT PANEL COMMANDS ............................................................................................... 1
6. MAXIMUM AND MINIMUM TEMPERATURE FUNCTIONS .................................................... 1
7. MAIN FUNCTIONS ............................................................................................................... 2
8. LIST OF PARAMETERS ....................................................................................................... 2
9. DIGITAL INPUTS .................................................................................................................. 2
10. INSTALLATION AND MOUNTING ......................................................................................... 3
11. ELECTRICAL CONNECTIONS.............................................................................................. 3
12. HOW TO USE THE HOT KEY .............................................................................................. 3
13. ALARM SIGNALS ................................................................................................................. 3
14. TECHNICAL DATA ............................................................................................................... 3
15. CONNECTIONS ................................................................................................................... 3
16. DEFAULT SETTING VALUES ............................................................................................... 3
1. GENERAL WARNING
1.1 PLEASE READ BEFORE USING THIS MANUAL
This manual is part of the product and should be kept near the instrument for easy and quick
reference.
The instrument shall not be used for purposes different from those described hereunder. It cannot
be used as a safety device.
Dixell Srl reserves the right to change the composition of its products, even without notice,
ensuring the same and unchanged functionality.
1.2 SAFETY PRECAUTIONS
Check the supply voltage is correct before connecting the instrument.
Do not expose to water or moisture: use the controller only within the operating limits avoiding
sudden temperature changes with high atmospheric humidity to prevent formation of
condensation
Warning: disconnect all electrical connections before any kind of maintenance.
The instrument must not be opened.
Fit the probe where it is not accessible by the end user.
In case of failure or faulty operation send the instrument back to the distributor or to Dixell S.r.l.
(see address) with a detailed description of the fault.
Consider the maximum current which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from
each other, without crossing or intertwining.
In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel
with inductive loads could be useful.
2. GENERAL DESCRIPTION
Models XR08CX, 32x74mm format, is a microprocessor based controllers suitable for application in the
milk preservation / refrigeration sector. It is equipped with one thermostat probe and two relay outputs to
control the compressor and agitator.
The XR08CX allows a very accurate control of all the main functions required during the "milk-tank
preservation" cycles, including the timed cycles of agitator functions. The operator can also manually
start a timed agitation cycle by pushing the UP key on the instrument's front panel.
Each instrument is fully configurable through special parameters that can be easily programmed through
the keypad.
3. CONTROLLING LOADS
3.1 THE COMPRESSOR
The regulation is performed
according to the temperature
measured by the thermostat probe
with a positive differential from the set
point: if the temperature increases
and reaches set point plus differential
the compressor is started and then
turned off when the temperature
reaches the set point value again.
In case of fault in the thermostat
probe the start and stop of the
compressor are timed through
parameters Con and CoF.

Precision Temperature Control for Dairy Applications

The DIXELL XR08CX-5NOC1 controller is tailored for milk chillers, delivering precise temperature management to ensure that dairy products remain fresh and safe. Its advanced functionality is vital for maintaining consistent cooling, which is essential in preventing spoilage and adhering to quality standards in milk storage and transportation.


Compact and Durable Design

Engineered with space-saving dimensions (32 x 74 x 50 mm), the controller fits effortlessly into tight panels. Crafted from durable PVC and weighing just 0.5 grams, it withstands daily industrial demands while maintaining a sleek, unobtrusive profile. Its robust build assures long-term, maintenance-free operation.

FAQ's of DIXELL CONTROLLER XR08CX-5NOC1:


Q: How do I install the DIXELL XR08CX-5NOC1 controller in a milk chiller system?

A: To install the XR08CX-5NOC1 controller, position it in the control panel, connect the wiring according to the product diagram for 230V operation, and ensure all sensors and relays are properly attached. Its compact dimensions allow easy integration into most standard milk chiller panels.

Q: What are the benefits of using this controller in milk chiller applications?

A: The major benefits include precise temperature regulation at 3 Delisle, enhancing product safety and quality, easy operation, energy efficiency, and reliable performance even under demanding conditions. This helps reduce spoilage and ensure compliance with dairy storage standards.

Q: When should I consider replacing my current milk chiller controller with the DIXELL XR08CX-5NOC1?

A: Consider upgrading if your current controller lacks temperature accuracy, is not compatible with 230V systems, or is not designed for the specific requirements of milk chilling. The XR08CX-5NOC1 offers improved reliability and modern features ideal for dairy environments.

Q: Where is the best place to mount the DIXELL XR08CX-5NOC1 controller?

A: Mount the controller on the front panel of your milk chiller or in a location that's easily accessible for monitoring and adjustments. Its compact size allows flexible installation even in limited spaces.

Q: What process does the controller follow to regulate milk chiller temperature?

A: The controller continuously monitors the chiller's internal temperature, compares it to the user-defined setpoint, and cycles the compressor or cooling mechanism on or off as needed to maintain the desired range, ensuring reliable milk preservation.

Q: Is the DIXELL XR08CX-5NOC1 suitable for other applications besides milk chillers?

A: While specifically designed for milk chiller applications, its robust temperature control features and compatibility with 230V systems make it adaptable for other cooling or refrigeration units requiring precise temperature management, provided they match the technical specifications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Temperature Controller Category

DIXELL CONTROLLER XR06CX-5NOC1

DIXELL CONTROLLER XR06CX-5NOC1

Price 2675.0 INR / Number

Minimum Order Quantity : 5

Temperature Range : Storage temperature: 25T60 C (13T140 F) Celsius (oC)

Type : Electronic

Cooling System : Operating temperature: 0T60 C (32T140 F)

Theory : Temperature Controller

XR70CX Dixell Controller

XR70CX Dixell Controller

Price 5350.0 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature Range : 50C to 110C

Type : Other , Digital Temperature Controller

Cooling System : Relay Output

Theory : Other, Microprocessor Based

DIXELL CONTROLLER XR70CX-5NOC1

DIXELL CONTROLLER XR70CX-5NOC1

Price 5000.0 INR / Number

Minimum Order Quantity : 3

Temperature Range : 0 TO 60 Celsius (oC)

Type : Electronic

Cooling System : COOLING PLANT

DIXELL CONTROLLER XR03cx-5noc1

DIXELL CONTROLLER XR03cx-5noc1

Price 2300.0 INR / Number

Minimum Order Quantity : 5

Temperature Range : 0TO 60 Celsius (oC)



arrow